MS27401-15
Relays and Solenoids
RELAY,ELECTROMAGNETIC
MS27401-15
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Main Contact Load Current Rating At Maximum Rated Voltage
10.0 amperes ac resistive load and 10.0 amperes dc resistive load
-
Mounting Facility Pattern
in-line single mounting facility
-
Duty Type
continuous
-
Time Delay
0.05 seconds maximum fixed release time
-
Main Contact Load Current Rating At Maximum Rated Voltage
8.0 amperes ac inductive load and 8.0 amperes dc inductive load
-
Center To Center Distance Between Mounting Facilities Parallel To Length
1.396 inches minimum single mounting facility and 1.446 inches maximum single mounting facility
-
Coil Quantity
1
-
Overall Width
0.505 inches minimum and 0.525 inches maximum
-
Purpose For Which Designed
general
-
Nominal Operating Current Rating And Type
40.0 milliamperes ac single winding
-
Mounting Slot Width
0.140 inches minimum single mounting facility and 0.160 inches maximum single mounting facility
-
Time Delay
0.015 seconds maximum fixed operate time
-
Specification/Standard Data
96906-ms27401 government standard
-
Main Contact Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc
-
Terminal Type And Quantity
8 wire hook all functions
-
Main Contact Load Current Rating At Maximum Rated Voltage
2.0 amperes ac lamp load and 2.0 amperes dc lamp load
-
Special Features
failure rate level 0.3 percent
-
Frequency In Hertz
400.0 nominal
-
Features Provided
polarized
-
Case Material
metal
-
Test Data Document
81349-mil-r-6106 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
~1
data on certain environmental and performance
-
Winding Quantity
1
-
Mounting Facility Type And Quantity
2 slotted hole single mounting facility
-
Arc Quenching Method
air
-
Cubic Measure
1.015 cubic inches
-
Environmental Protection
hermetic
-
Operating Voltage Rating And Type At Specified Temp
115.0 volts ac 25 deg celsius single winding
-
Overall Height
1.105 inches minimum and 1.125 inches maximum
-
Nonpile-Up Main Contact Arrangement
2 pole, double throw, one position momentary
-
Criticality Code Justification
feat
-
Storage Type
general purpose warehouse
-
Overall Length
1.698 inches minimum and 1.718 inches maximum
-
Main Contact Load Current Rating At Maximum Rated Voltage
4.0 amperes ac motor load and 4.0 amperes dc motor load
-
Fragility Factor
moderately rugged