1324AS153

Circuit Breakers

CIRCUIT BREAKER

1324AS153

5925-01-288-4143

5925 - Circuit Breakers

Naval Air Systems Command

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches maximum

  • Internal Trip Release Configuration

    shunt trip second location

  • Thread Series Designator

    unef

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.500 minimum at 200 pct all locations and 9.000 maximum at 200 pct all locations

  • Body Width

    1.281 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    4.0 amperes ac first location and 4.0 amperes dc first location

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Terminal Type And Quantity

    5 wire hook

  • Bushing Length

    0.332 inches minimum and 0.380 inches maximum

  • Reset Method

    manual

  • Center To Center Distance Between Terminals Parallel To Width

    0.594 inches minimum and 0.656 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    250.0 milliamperes ac second location and 250.0 milliamperes dc second location

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Mounting Surface To Terminal End Distance

    1.828 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac all locations and 500.0 dc all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations and 50.0 dc all locations

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

  • Body Length

    1.552 inches maximum

  • Trip Release Method

    magnetic all locations

  • Internal Trip Release Configuration

    series trip first location

  • Actuator Position Designation

    at pole two

  • Inclosure Protection Type For Which Designed

    hermetically sealed

  • Body Style

    multipole-single actuator type

  • Case Material

    metal

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Arc Quenching Method

    magnetic blowout

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...