Technical Characteristics
-
Fragility Factor
moderately rugged
-
Mounting Facility Pattern
rectangular single mounting facility
-
Storage Type
general purpose warehouse
-
Center To Center Distance Between Mounting Facilities Parallel To Length
1.396 inches minimum single mounting facility and 1.446 inches maximum single mounting facility
-
Main Contact Load Current Rating At Maximum Rated Voltage
15.0 amperes ac inductive load and 12.0 amperes dc inductive load
-
Duty Type
continuous
-
Center To Center Distance Between Mounting Facilities Parallel To Width
0.625 inches nominal single mounting facility
-
Nonpile-Up Auxiliary Contact Arrangement
1 pole, double throw, two positions momentary
-
Overall Width
1.000 inches nominal
-
Time Delay
0.015 seconds maximum fixed operate and release time
-
Auxiliary Contact Load Current Rating At Maximum Rated Voltage
500.0 milliamperes ac lamp load and 500.0 milliamperes dc lamp load
-
Mounting Slot Width
0.150 inches nominal single mounting facility
-
End Item Identification
control unit
-
Winding Quantity
1
-
Overall Length
1.718 inches maximum
-
Main Contact Load Current Rating At Maximum Rated Voltage
25.0 amperes ac resistive load and 25.0 amperes dc resistive load
-
Auxiliary Contact Load Current Rating At Maximum Rated Voltage
1.0 amperes ac inductive load and 1.0 amperes dc inductive load
-
Mounting Facility Type And Quantity
4 slotted hole single mounting facility
-
Terminal Type And Quantity
11 wire hook all functions
-
Main Contact Load Current Rating At Maximum Rated Voltage
10.0 amperes ac motor load and 10.0 amperes dc motor load
-
Operating Voltage Rating And Type At Specified Temp
29.0 volts dc 25 deg celsius single winding
-
Overall Height
1.015 inches nominal
-
Auxiliary Contact Load Current Rating At Maximum Rated Voltage
2.0 amperes ac resistive load and 2.0 amperes dc resistive load
-
Nonpile-Up Main Contact Arrangement
3 pole, single throw, normally open, momentary action
-
Main Contact Maximum Voltage Rating In Volts
200.0 ac and 28.0 dc
-
Main Contact Load Current Rating At Maximum Rated Voltage
5.0 amperes ac lamp load and 5.0 amperes dc lamp load
-
Purpose For Which Designed
general
-
Coil Quantity
1
-
Winding Dc Resistance Rating
290.0 ohms nominal single winding