NF21192-2

Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

NF21192-2

5915-01-289-4667

5915 - Filters and Networks

Corcom Inc

FILTER,RADIO FREQUENCY INTERFERENCE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Principal Circuitry Type Per Function

    inductance-capacitance 4th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    60.0 4th radio interference

  • Inclosure Type

    hermetically sealed

  • Special Features

    removeable terminal covers

  • Functional Terminal Type And Quantity

    4 threaded stud output 2nd function

  • Vibration Resistance Range In Hertz

    +5.0/+200.0

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 4th radio interference 4th function

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 1st radio interference 1st function

  • Principal Circuitry Type Per Function

    inductance-capacitance 1st radio interference

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Principal Circuitry Type Per Function

    inductance-capacitance 3rd radio interference

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 3rd radio interference 3rd function

  • Power Line Frequency Rating Per Function In Hertz

    60.0 1st radio interference

  • Body Width

    10.100 inches minimum and 10.160 inches maximum

  • Specification/Standard Data

    80063-sm-a-919007 manufacturers source control

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 2nd radio interference 2nd function

  • Power Line Frequency Rating Per Function In Hertz

    60.0 2nd radio interference

  • Unpackaged Unit Weight

    12.000 pounds

  • Operating Current Rating Per Function In Amps

    30.0 1st radio interference

  • Body Length

    7.600 inches minimum and 7.660 inches maximum

  • Maximum Temp Rise

    60.0 deg celsius

  • Power Line Frequency Rating Per Function In Hertz

    60.0 3rd radio interference

  • Operating Current Rating Per Function In Amps

    30.0 2nd radio interference

  • Overall Length

    13.600 inches minimum and 13.660 inches maximum

  • Overall Height

    2.530 inches minimum and 2.590 inches maximum

  • Operating Current Rating Per Function In Amps

    30.0 3rd radio interference

  • Operating Current Rating Per Function In Amps

    30.0 4th radio interference

  • Operating Temp Range

    -46.0/+85.0 deg celsius

  • Principal Circuitry Type Per Function

    inductance-capacitance 2nd radio interference

  • Functional Terminal Type And Quantity

    4 threaded stud input 1st function

  • Unthreaded Mounting Hole Diameter

    0.281 inches nominal

  • Style Designator

    rectangular terminal/terminals on opposite surfaces

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...