M6106/46-001
Relays and Solenoids
RELAY,ELECTROMAGNETIC
M6106/46-001
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Test Data Document
81349-mil-r-6106 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
~1
data on certain environmental and performance
-
Auxiliary Contact Load Current Rating At Maximum Rated Voltage
5.0 amperes ac inductive load and 5.0 amperes dc inductive load
-
Center To Center Distance Between Mounting Facilities Parallel To Width
2.833 inches minimum single mounting facility and 2.853 inches maximum single mounting facility
-
Cubic Measure
73.130 cubic inches
-
Main Contact Load Current Rating At Maximum Rated Voltage
120.0 amperes ac inductive load
-
Auxiliary Contact Load Current Rating At Maximum Rated Voltage
1.0 amperes ac lamp load and 1.0 amperes dc lamp load
-
Terminal Type And Quantity
9 threaded stud contacts
-
Main Contact Load Current Rating At Maximum Rated Voltage
120.0 amperes ac resistive load
-
Purpose For Which Designed
general
-
Coil Quantity
1
-
Specification/Standard Data
81349-mil-r-6106/46 government specification
-
Nonpile-Up Main Contact Arrangement
3 pole, double throw, one position momentary
-
Operating Voltage Rating And Type At Specified Temp
30.0 volts dc 25 deg celsius single winding
-
Overall Width
3.560 inches minimum and 3.620 inches maximum
-
Duty Type
continuous
-
Unthreaded Mounting Hole Diameter
0.208 inches minimum single mounting facility and 0.228 inches maximum single mounting facility
-
Fragility Factor
moderately rugged
-
Main Contact Load Current Rating At Maximum Rated Voltage
80.0 amperes ac motor load
-
Terminal Type And Quantity
1 connector, receptacle energizing element
-
Mounting Facility Type And Quantity
4 unthreaded hole single mounting facility
-
Mounting Facility Pattern
rectangular single mounting facility
-
Storage Type
general purpose warehouse
-
Nonpile-Up Auxiliary Contact Arrangement
6 pole, double throw, one position momentary
-
Overall Height
4.220 inches minimum and 4.280 inches maximum
-
Auxiliary Contact Load Current Rating At Maximum Rated Voltage
5.0 amperes ac resistive load and 5.0 amperes dc resistive load
-
Environmental Protection
hermetic
-
Auxiliary Contact Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc
-
Arc Quenching Method
air
-
Winding Quantity
1
-
Overall Length
4.660 inches minimum and 4.720 inches maximum
-
Center To Center Distance Between Mounting Facilities Parallel To Length
3.927 inches minimum single mounting facility and 3.947 inches maximum single mounting facility
-
Case Material
metal
-
Main Contact Maximum Voltage Rating In Volts
200.0 ac