18100357-003
Circuit Breakers
CIRCUIT BREAKER
18100357-003
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.025 minimum at 200 pct single location and 6.000 maximum at 200 pct
-
Terminal Type And Quantity
2 tab w/screw
-
Body Style
1a single pole type
-
Body Width
0.656 inches maximum
-
Case Material
plastic
-
Arc Quenching Method
magnetic blowout
-
Operating Voltage Type And Rating Per Pole In Volts
32.0 dc single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 dc single location
-
Circuit Protection Type
overcurrent single location
-
Trip Release Method
magnetic single location
-
Trip Release Characteristic
time delay single location
-
Reset Method
manual
-
Main Contact Tripping Mechanism Type
trip free
-
Actuator Position Designation
at pole one
-
Bushing Length
0.548 inches minimum and 0.648 inches maximum
-
Body Length
1.761 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
1.209 inches minimum and 1.271 inches maximum
-
Fragility Factor
moderately rugged
-
Mounting Surface To Terminal End Distance
1.776 inches minimum and 1.838 inches maximum
-
Pole Quantity
1
-
Mounting Facility Type And Quantity
1 threaded bushing
-
Storage Type
general purpose warehouse
-
Thread Quantity Per Inch
32
-
Maximum Continuous Load Current Rating Per Pole
4.2 amperes dc single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
-
Manual Actuator Type And Quantity
1 push-pull
-
Actuator Function
trip-reset
-
Internal Trip Release Configuration
series trip single location
-
Nominal Thread Size
0.468 inches
-
Inclosure Protection Type For Which Designed
dustproof
-
Thread Series Designator
uns