WT-C0069-005
Circuit Breakers
CIRCUIT BREAKER
WT-C0069-005
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Fragility Factor
moderately rugged
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Center To Center Distance Between Terminals Parallel To Width
0.735 inches minimum and 0.765 inches maximum
-
Inclosure Protection Type For Which Designed
salt spray proof and vibration resistant and shock resistant and moisture resistant and fungus resistant
-
Special Features
includes barriers between poles
-
Trip Release Method
magnetic all locations
-
Body Style
multipole-multiple actuator type
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Mounting Facility Type And Quantity
6 threaded hole
-
Center To Center Distance Between Terminals Parallel To Length
1.930 inches minimum and 1.950 inches maximum
-
Body Width
2.265 inches maximum
-
Nominal Thread Size
0.138 inches
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.735 inches minimum and 0.765 inches maximum
-
Boss Height
0.140 inches minimum and 0.160 inches maximum
-
Main Contact Tripping Mechanism Type
trip free
-
Arc Quenching Method
magnetic blowout
-
Frequency In Hertz
50.0 all locations or 60.0 all locations
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
-
Body Length
2.480 inches minimum and 2.500 inches maximum
-
Manual Actuator Type And Quantity
3 toggle
-
Case Material
plastic
-
Terminal Type And Quantity
6 threaded stud
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.170 minimum at 200 pct all locations and 1.900 maximum at 200 pct all locations
-
Thread Series Designator
unc
-
Actuator Position Designation
at each pole
-
Reset Method
manual
-
Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
External Actuator Linkage Arrangement
one, two, and three linked
-
Internal Trip Release Configuration
series trip all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.050 inches minimum and 2.070 inches maximum
-
Thread Quantity Per Inch
32
-
Maximum Continuous Load Current Rating Per Pole
80.0 amperes ac all locations
-
Mounting Surface To Terminal End Distance
2.905 inches minimum and 3.055 inches maximum