A517A085-101
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
A517A085-101
Murata Erie North America Inc Divof
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Distance Between Mounting Surface And Lower End
0.813 inches minimum and 0.905 inches maximum
-
Inclosure Type
hermetically sealed
-
Functional Terminal Type And Quantity
12 tab, solder lug input
-
Operating Voltage Rating And Type Per Function
250.0 volts ac 3rd radio interference and 350.0 volts dc 3rd radio interference
-
Body Surface Treatment
tin
-
Unpackaged Unit Weight
50.0 grams
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference
-
Source Impedance Rating Per Function
50.0 ohms 5th radio interference
-
Source Impedance Rating Per Function
50.0 ohms 6th radio interference
-
Load Impedance Per Function
50.0 ohms 3rd radio interference
-
Load Impedance Per Function
50.0 ohms 6th radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 2nd radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 5th radio interference
-
Operating Current Rating Per Function In Amps
10.0 2nd radio interference
-
Operating Current Rating Per Function In Amps
10.0 5th radio interference
-
Maximum Voltage Drop Per Function
90.0 millivolts dc 2nd radio interference
-
Maximum Voltage Drop Per Function
90.0 millivolts dc 3rd radio interference
-
Maximum Voltage Drop Per Function
90.0 millivolts dc 4th radio interference
-
Maximum Voltage Drop Per Function
90.0 millivolts dc 6th radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 1st radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 2nd radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 3rd radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 4th radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 6th radio interference
-
Mounting Facility Type And Quantity
4 slot
-
Functional Terminal Type And Quantity
12 tab, solder lug output
-
Operating Voltage Rating And Type Per Function
250.0 volts ac 1st radio interference and 350.0 volts dc 1st radio interference
-
Operating Voltage Rating And Type Per Function
250.0 volts ac 2nd radio interference and 350.0 volts dc 2nd radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 4th radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 6th radio interference
-
Operating Current Rating Per Function In Amps
10.0 1st radio interference
-
Operating Current Rating Per Function In Amps
10.0 3rd radio interference
-
Operating Current Rating Per Function In Amps
10.0 4th radio interference
-
Operating Current Rating Per Function In Amps
10.0 6th radio interference
-
Maximum Voltage Drop Per Function
90.0 millivolts dc 1st radio interference
-
Maximum Voltage Drop Per Function
90.0 millivolts dc 5th radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 5th radio interference
-
Overall Length
1.422 inches minimum and 1.452 inches maximum
-
Body Height
1.156 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
0.865 inches minimum and 0.885 inches maximum
-
Operating Temp Range
-55.0 to 125.0 deg celsius
-
Operating Voltage Rating And Type Per Function
250.0 volts ac 4th radio interference and 350.0 volts dc 4th radio interference
-
Operating Voltage Rating And Type Per Function
250.0 volts ac 5th radio interference and 350.0 volts dc 5th radio interference
-
Operating Voltage Rating And Type Per Function
250.0 volts ac 6th radio interference and 350.0 volts dc 6th radio interference
-
Body Material
metal
-
Special Features
12 functions
-
Style Designator
16 rectangular terminal/terminals on opposite surfaces
-
Overall Height
1.780 inches maximum
-
Mounting Slot Width
0.125 inches minimum and 0.130 inches maximum
-
Body Length
0.965 inches minimum and 0.985 inches maximum
-
Body Width
0.700 inches minimum and 0.720 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.490 inches minimum and 0.510 inches maximum
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Source Impedance Rating Per Function
50.0 ohms 4th radio interference
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Load Impedance Per Function
50.0 ohms 4th radio interference
-
Load Impedance Per Function
50.0 ohms 5th radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 1st radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 3rd radio interference