APL-1-1REC2-51-253A

Circuit Breakers

CIRCUIT BREAKER

APL-1-1REC2-51-253A

5925-01-293-1294

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Terminal Type And Quantity

    2 threaded stud

  • Thread Series Designator

    iso m

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 50.0 dc

  • Switch Current Rating And Type In Amps

    10.0 ac and 3.0 dc

  • Switch Terminal Type

    quick disconnect,male

  • Inclosure Protection Type For Which Designed

    moisture resistant and salt spray proof and shock resistant and vibration resistant

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.100 minimum at 200 pct and 1.700 maximum at 200 pct

  • Thread Pitch In Millimeters

    0.50

  • Nominal Thread Size

    3.0 millimeters

  • Actuator Position Designation

    at pole one

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Reset Method

    manual

  • Trip Release Characteristic

    time delay

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 dc

  • Operating Voltage Type And Rating Per Pole In Volts

    65.0 dc

  • Storage Type

    general purpose warehouse

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Arc Quenching Method

    magnetic blowout

  • Center To Center Distance Between Terminals Parallel To Length

    1.925 inches minimum and 1.955 inches maximum

  • Body Length

    2.480 inches minimum and 2.500 inches maximum

  • Switch Location And Position Designation

    internal at pole one

  • Internal Trip Release Configuration

    series trip

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0

  • Trip Release Method

    magnetic

  • Circuit Protection Type

    overcurrent

  • Maximum Continuous Load Current Rating Per Pole

    25.0 amperes dc

  • Special Handling Feature

    magnetic

  • Pole Quantity

    1

  • Mounting Surface To Terminal End Distance

    2.491 inches maximum

  • Boss Height

    0.135 inches minimum and 0.165 inches maximum

  • Fragility Factor

    moderately rugged

  • Switch Contact Arrangement

    single pole,double throw

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.050 inches minimum and 2.070 inches maximum

  • Case Material

    plastic

  • Body Width

    0.750 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...