86094-008B2

Circuit Breakers

CIRCUIT BREAKER

86094-008B2

5925-01-294-1245

5925 - Circuit Breakers

Dla Land And Maritime

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Length

    1.970 inches minimum and 2.030 inches maximum

  • Switch Contact Arrangement

    single pole, double throw

  • Boss Height

    0.094 inches minimum and 0.156 inches maximum

  • Mounting Facility Type And Quantity

    2 terminal

  • Storage Type

    general purpose warehouse

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac single location and 50.0 dc

  • Trip Release Method

    magnetic single location

  • Trip Release Characteristic

    time delay single location

  • Actuator Position Designation

    at pole one

  • Internal Trip Release Configuration

    series trip single location

  • Switch Location And Position Designation

    internal at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.500 minimum at 200 pct single location and 9.000 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    fungus resistant and vibration resistant

  • Frequency In Hertz

    60.0 single location or 400.0

  • Special Features

    item includes illuminated handle

  • Terminal Type And Quantity

    2 tab, solder lug

  • Body Style

    10a single pole type

  • Body Width

    0.889 inches minimum and 0.951 inches maximum

  • Body Height

    1.341 inches minimum and 1.801 inches maximum

  • Case Material

    plastic

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    1

  • Arc Quenching Method

    magnetic blowout

  • Maximum Continuous Load Current Rating Per Pole

    500.0 milliamperes ac single location and 500.0 milliamperes dc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac single location and 500.0 dc

  • Circuit Protection Type

    overcurrent single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Auxiliary Switch Function And Quantity

    1 alarm

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...