T3517
Coils and Transformers
TRANSFORMER,PULSE
T3517
TRANSFORMER,PULSE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Winding Function And Quantity
2 primary single component and 4 secondary single component
-
Winding Operating Current
707.0 milliamperes nominal b single component all primary
-
Winding Shielding Method
internally shielded and brought out to primary terminal single component
-
Terminal Type And Quantity
17 wire lead
-
Body Length
1.660 inches minimum and 1.700 inches maximum
-
Maximum Operating Temp
170.0 deg celsius
-
Winding Tap Location (Non-Core)
tap w/o center tap single component all secondary
-
Inclosure Type
fully inclosed
-
Dc Resistance Rating In Ohms
1.000 single component all primary
-
Body Height
0.680 inches minimum and 0.720 inches maximum
-
Dc Resistance Rating In Ohms
0.150 single component all secondary
-
Reliability Indicator
not established
-
Mounting Method
terminal single group
-
Pulse Duration In Microseconds (Non-Core)
33.000 single component
-
Winding Operating Current
1.06 amperes nominal b single component all secondary
-
Frequency Rating
15.0 kilohertz nominal single component
-
Unpackaged Unit Weight (Non-Core)
70.0 grams
-
Body Width
0.980 inches minimum and 1.020 inches maximum
-
Peak Voltage Rating (Non-Core)
12.0 volts single component all primary
-
Inductance Rating
1.90 millihenries minimum single component all primary