T5959
Coils and Transformers
TRANSFORMER,POWER
T5959
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Winding Function And Quantity
1 primary single component and 3 secondary single component
-
Body Length
2.360 inches maximum
-
Body Width
1.740 inches maximum
-
Winding Operating Voltage
5.00 dc volts nominal single component 3rd secondary
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.290 inches minimum single mounting facility single center group and 1.310 inches maximum single mounting facility single center group
-
Mounting Facility Quantity
4 single group
-
Specification/Standard Data
53711-6127564 manufacturers source control
-
Winding Operating Current
5.0 amperes ac maximum single component single primary
-
Winding Operating Voltage
36.00 ac volts nominal single component single primary
-
Winding Shielding Method
internal shield grounded to inclosure and core single component
-
Winding Operating Current
30.0 amperes ac maximum single component 1st secondary
-
Winding Operating Current
0.1 amperes ac maximum single component 3rd secondary
-
Inclosure Type
fully inclosed
-
Winding Operating Current
1.44 amperes ac maximum single component 2nd secondary
-
Center To Center Distance Between Mounting Facilities Parallel To Length
1.890 inches minimum single mounting facility single center group and 1.910 inches maximum single mounting facility single center group
-
Winding Operating Voltage
6.00 dc volts nominal single component 1st secondary
-
Mounting Method
unthreaded hole single group
-
Body Height
1.210 inches minimum and 1.250 inches maximum
-
Frequency Rating
100.0 kilohertz nominal single component
-
Reliability Indicator
not established
-
Winding Operating Voltage
6.00 dc volts nominal single component 2nd secondary
-
Input-Output Phase Relationship
single phase to single phase single component
-
Terminal Type And Quantity
8 turret
-
Mounting Hole Diameter
0.170 inches minimum single group and 0.190 inches maximum single group