1332R5KL.5
Resistors
RESISTOR,VARIABLE,NONWIRE WOUND,PRECISION
1332R5KL.5
Bei Sensors & Systems Company Inc.
RESISTOR,VARIABLE,NONWIRE WOUND,PRECISION
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Undercut Diameter
1.125 inches maximum
-
Fragility Factor
moderately rugged
-
Power Dissipation Rating Per Section In Watts
0.5 7th secondary quality
-
Terminal Type And Quantity
3 turret
-
Shaft End Play
0.005 inches
-
Effective Electrical Rotation In Deg Angular Rotation
340.0 nominal
-
Function Conformity Per Section
single section independent linearity
-
Shaft Bearing Type
bearing
-
End Item Identification
remote cont s
-
Maximum Starting Torque
0.20 inch-ounces
-
Mechanical Backlash In Deg Angular Rotation
0.25
-
Pilot Diameter Runout
0.001 inches
-
Shaft Style
round
-
Body Diameter
1.250 nominal centimeters
-
Shaft Length
0.5945 inches minimum and 0.6565 inches maximum
-
Undercut Width
0.0570 inches minimum
-
Section Quantity
1
-
Shaft Runout
0.002 inches
-
~1
section
-
Shaft Radial Play
0.001 inches
-
Body Style
cylindrical servo mounted
-
Maximum Running Torque
0.20 inch-ounces
-
Shaft Diameter
0.1245 inches minimum and 0.1250 inches maximum
-
Actuator Travel Control Feature
clutch
-
Ambient Temp In Deg Celsius Per Section At Zero Percent Rated Power
125.0 single section
-
Rotary Actuator Travel In Angular Deg
360.0 nominal
-
Lateral Runout
0.002 inches
-
Mounting Lip Diameter
1.0520 inches minimum and 1.0670 inches maximum
-
Body Length
0.810 inches maximum
-
Actuator Type
single shaft
-
Reliability Indicator
not established
-
Function Conformity Tolerance Per Section
-0.50/+0.50 single section
-
Mounting Method
clamp ring
-
Cubic Measure
0.994 cubic inches
-
Terminal Location
radially positioned over less than half the circumference
-
Resistance Tolerance Per Section In Percent
-10.0/+10.0 single section
-
Mounting Lip Depth
0.0570 nominal mils and 0.0670 nominal centimeters
-
Pilot Diameter
0.9683 inches minimum and 0.9688 inches maximum
-
Features Provided
humidity proof
-
Pilot Length
0.0570 inches minimum and 0.0670 inches maximum
-
Electrical Resistance Per Section
5.0 percent, rated amperes c and better flooring
-
Function Characteristic Per Section
7 oclock all primaries
-
Ambient Temp In Deg Celsius Per Section At Full Rated Power
70.0 single section
-
Resistance Temp Characteristic Range Per Section In Percent
-5.0/+5.0 75 deg celsius single section and -4.0/+4.0 -15 deg celsius single section and -5.0/+5.0 -65 deg celsius single section and -2.5/+2.5 50 deg celsius single section and -5.0/+5.0 105 deg celsius single section and -5.0/+5.0 125 deg celsius single