10112314-101

Circuit Breakers

CIRCUIT BREAKER

10112314-101

5925-01-296-6695

5925 - Circuit Breakers

Honeywell International Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Terminal Type And Quantity

    2 quick disconnect, male

  • Frequency In Hertz

    400.0 single location

  • Inclosure Protection Type For Which Designed

    dustproof

  • Nominal Thread Size

    0.138 inches

  • Actuator Position Designation

    at pole one

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Reset Method

    manual

  • Trip Release Method

    magnetic-hydraulic single location

  • Circuit Protection Type

    overcurrent single location

  • Maximum Continuous Load Current Rating Per Pole

    1.0 amperes ac single location

  • Thread Quantity Per Inch

    32

  • Iii Arc Quenching Method

    magnetic blowout

  • Pole Quantity

    1

  • Mounting Surface To Terminal End Distance

    1.962 inches maximum

  • Mounting Surface To Terminal End Distance

    1.898 inches minimum and

  • Boss Height

    0.098 inches minimum and

  • Center To Center Distance Between Terminals Parallel To Length

    1.592 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.528 inches minimum and

  • Body Width

    0.718 inches minimum and

  • Body Style

    12a single pole type

  • Thread Series Designator

    unc

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.200 maximum at 200 pct single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.200 minimum at 200 pct and

  • Internal Trip Release Configuration

    series trip single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 single location

  • Trip Release Characteristic

    time delay single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac single location

  • Iii Storage Type

    general purpose warehouse

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Boss Height

    0.162 inches maximum

  • Iii Fragility Factor

    moderately rugged

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.692 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.628 inches minimum and

  • Case Material

    plastic

  • Body Width

    0.782 inches maximum

  • Body Length

    2.032 inches maximum

  • Body Length

    1.968 inches minimum and

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...