Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.660 inches nominal

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Storage Type

    general purpose warehouse

  • Switch Location And Position Designation

    internal at pole two

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Body Length

    2.000 inches nominal

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip all locations

  • Mounting Surface To Terminal End Distance

    2.032 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Body Style

    multipole-multiple actuator type

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 30.0 dc

  • Switch Contact Arrangement

    single pole, double throw

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Unpackaged Unit Weight

    6.600 ounces

  • Body Width

    2.265 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2100.0 ac all locations

  • Nominal Thread Size

    3.0 millimeters

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Switch Current Rating And Type In Amps

    10.0 ac and 5.0 dc

  • Arc Quenching Method

    magnetic blowout

  • Thread Pitch In Millimeters

    0.50

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.150 minimum at 200 pct all locations and 1.900 maximum at 200 pct all locations

  • Center To Center Distance Between Terminals Parallel To Length

    1.530 inches nominal

  • Special Features

    actuator black without markings

  • Frequency In Hertz

    400.0 all locations

  • Thread Series Designator

    iso m

  • Inclosure Protection Type For Which Designed

    shock resistant and hermetically sealed and vibration resistant

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Terminal Type And Quantity

    6 tab w/screw

  • Manual Actuator Type And Quantity

    3 toggle

  • Switch Terminal Type

    quick disconnect, male

  • Maximum Continuous Load Current Rating Per Pole

    2.5 amperes ac all locations

  • Case Material

    plastic

  • Boss Height

    0.130 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...