68-157344-4

Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

68-157344-4

5915-01-299-9233

5915 - Filters and Networks

Northrop Grumman Space & Mission

FILTER,RADIO FREQUENCY INTERFERENCE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Source Impedance Rating Per Function

    50.0 ohms 3rd radio interference

  • Overall Height

    2.005 inches nominal

  • Operating Current Rating Per Function In Amps

    10.0 2nd radio interference

  • Functional Terminal Type And Quantity

    8 tab, solder lug ground 3rd function

  • Principal Circuitry Type Per Function

    inductance-capacitance 1st radio interference

  • Body Material

    metal

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Operating Current Rating Per Function In Amps

    10.0 4th radio interference

  • Operating Current Rating Per Function In Amps

    10.0 3rd radio interference

  • Maximum Voltage Drop Per Function

    0.1 volts dc 1st radio interference

  • Functional Terminal Type And Quantity

    8 tab, solder lug output 2nd function

  • Operating Temp Range

    -55.0/+55.0 deg celsius

  • Body Surface Treatment

    tin

  • Load Impedance Per Function

    50.0 ohms 2nd radio interference

  • Body Length

    2.080 inches minimum and 2.120 inches maximum

  • Source Impedance Rating Per Function

    50.0 ohms 4th radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 6th radio interference

  • Inclosure Type

    encased

  • Operating Voltage Rating And Type Per Function

    50.0 volts dc 1st radio interference 1st function

  • Vibration Resistance Range In Hertz

    +5.0/+500.0

  • Source Impedance Rating Per Function

    50.0 ohms 1st radio interference

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.730 inches minimum and 1.750 inches maximum

  • Maximum Voltage Drop Per Function

    0.1 volts dc 6th radio interference

  • Operating Voltage Rating And Type Per Function

    50.0 volts dc 3rd radio interference 3rd function

  • Source Impedance Rating Per Function

    50.0 ohms 6th radio interference

  • Maximum Voltage Drop Per Function

    0.1 volts dc 5th radio interference

  • Load Impedance Per Function

    50.0 ohms 3rd radio interference

  • Maximum Voltage Drop Per Function

    0.1 volts dc 4th radio interference

  • Maximum Voltage Drop Per Function

    0.1 volts dc 3rd radio interference

  • Maximum Voltage Drop Per Function

    0.1 volts dc 2nd radio interference

  • Operating Voltage Rating And Type Per Function

    50.0 volts dc 2nd radio interference 2nd function

  • Operating Current Rating Per Function In Amps

    10.0 6th radio interference

  • Operating Current Rating Per Function In Amps

    10.0 5th radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 2nd radio interference

  • Functional Terminal Type And Quantity

    1 connector, receptacle input 1st function

  • Source Impedance Rating Per Function

    50.0 ohms 5th radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 5th radio interference

  • Input Terminal Identification

    ms27505e21f16p

  • Overall Length

    2.410 inches maximum

  • Body Width

    2.120 inches maximum

  • Load Impedance Per Function

    50.0 ohms 1st radio interference

  • Maximum Temp Rise

    20.0 deg celsius

  • Load Impedance Per Function

    50.0 ohms 6th radio interference

  • Maximum Dielectric Withstanding Dc Voltage

    125.0 volts at sea level

  • Principal Circuitry Type Per Function

    inductance-capacitance 4th radio interference

  • Load Impedance Per Function

    50.0 ohms 5th radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 2nd radio interference

  • Input Terminal Manufacturer Code

    96906

  • Body Height

    1.380 inches maximum

  • Operating Current Rating Per Function In Amps

    10.0 1st radio interference

  • Nominal Thread Size

    0.112 inches

  • Mounting Facility Screw Thread Series Designator

    unc

  • Operating Voltage Rating And Type Per Function

    50.0 volts dc 6th radio interference 6th function

  • Principal Circuitry Type Per Function

    inductance-capacitance 3rd radio interference

  • Load Impedance Per Function

    50.0 ohms 4th radio interference

  • Operating Voltage Rating And Type Per Function

    50.0 volts dc 5th radio interference 5th function

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.730 inches minimum and 1.750 inches maximum

  • Style Designator

    rectangular terminal/terminals on two surfaces

  • Operating Voltage Rating And Type Per Function

    50.0 volts dc 4th radio interference 4th function

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...