SM-A-919348-1
Coils and Transformers
TRANSFORMER,RADIO FREQUENCY
SM-A-919348-1
TRANSFORMER,RADIO FREQUENCY
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Rating Method
winding turns single component single secondary
-
Body Length
0.350 inches maximum
-
Turn Quantity
59 single component single secondary
-
Frequency Rating
35.0 kilohertz nominal single component
-
Test Data Document
80063-sm-a-919348 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Rating Method
electrical single component single primary and winding turns single component single primary
-
Inclosure Type
fully inclosed
-
Winding Function And Quantity
1 primary single component and 1 secondary single component
-
Inductance Rating
27.50 millihenries nominal single component single primary
-
Terminal Type And Quantity
5 wire lead
-
Body Outside Diameter
0.650 inches maximum
-
Reliability Indicator
not established
-
Turn Quantity
100 single component single primary
-
Coil Form Type
solid single component
-
Mounting Method
terminal single group
-
Winding Conductor Size
0.01264 inches american wire gage single component single primary
-
Winding Tap Location (Non-Core)
center tap single component single primary
-
Winding Conductor Size
0.01264 inches american wire gage single component single secondary
-
End Item Identification
7021-01-177-0790