AP-112-1-42F-302

Circuit Breakers

CIRCUIT BREAKER

AP-112-1-42F-302

5925-01-300-6809

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic all locations

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Actuator Position Designation

    at pole two

  • Maximum Continuous Load Current Rating Per Pole

    3.0 amperes ac all locations

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Body Style

    multipole-single actuator type

  • Inclosure Protection Type For Which Designed

    hermetically sealed and shockproof and vibrationproof

  • Case Material

    metal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Body Width

    1.937 inches maximum

  • Main Contact Tripping Mechanism Type

    trip free

  • Body Length

    1.562 inches maximum

  • Frequency In Hertz

    400.0 all locations

  • Thread Series Designator

    unef

  • Fragility Factor

    moderately rugged

  • Trip Release Characteristic

    instantaneous all locations

  • Special Handling Feature

    magnetic

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac all locations

  • Terminal Type And Quantity

    6 wire hook

  • Unpackaged Unit Weight

    11.100 ounces

  • Bushing Length

    0.380 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.