GJ3-A3-DU-125-240-1

Circuit Breakers

CIRCUIT BREAKER

GJ3-A3-DU-125-240-1

5925-01-300-8939

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Circuit Protection Type

    overcurrent all locations

  • Actuator Position Designation

    at each pole

  • Nominal Thread Size

    0.190 inches

  • Reset Method

    manual

  • Body Width

    4.469 inches minimum and 4.531 inches maximum

  • Thread Series Designator

    unf

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip all locations

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Body Length

    7.094 inches minimum and 7.156 inches maximum

  • Trip Release Method

    magnetic-hydraulic all locations

  • Maximum Continuous Load Current Rating Per Pole

    125.0 amperes ac all locations

  • Body Style

    multipole-multiple actuator type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Boss Height

    0.188 inches minimum and 0.250 inches maximum

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    3.812 inches minimum and 3.844 inches maximum

  • Mounting Surface To Terminal End Distance

    4.282 inches minimum and 4.344 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    1.469 inches minimum and 1.531 inches maximum

  • Frequency In Hertz

    60.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    3

  • Trip Delay Time In Seconds Per Rated Continuous Current

    20.000 minimum at 200 pct all locations and 120.000 maximum at 200 pct all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.469 inches minimum and 1.531 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    18000.0 ac all locations

  • Manual Actuator Type And Quantity

    3 toggle

  • Center To Center Distance Between Terminals Parallel To Length

    5.968 inches minimum and 6.030 inches maximum

  • Case Material

    plastic

  • Terminal Type And Quantity

    6 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...