64510026D

Circuit Breakers

CIRCUIT BREAKER

64510026D

5925-01-301-1984

5925 - Circuit Breakers

Thales Training & Simulation Ltd

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Switch Terminal Type

    tab, solder lug

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Body Length

    2.500 inches nominal

  • Boss Height

    0.140 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Manual Actuator Type And Quantity

    2 toggle

  • Frequency In Hertz

    400.0 all locations

  • Inclosure Protection Type For Which Designed

    humidity resistant and shock resistant and fungus resistant and moisture resistant and vibration resistant

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Terminal Type And Quantity

    4 threaded stud

  • Mounting Surface To Terminal End Distance

    2.481 inches nominal

  • Body Width

    1.500 inches nominal

  • External Actuator Linkage Arrangement

    one and two linked

  • Switch Location And Position Designation

    internal at pole one

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.938 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.062 inches nominal

  • Internal Trip Release Configuration

    series trip w/auxiliary load terminal first location

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Special Handling Feature

    magnetic

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Switch Voltage Rating And Type In Volts

    50.0 ac

  • Storage Type

    general purpose warehouse

  • Switch Current Rating And Type In Amps

    10.0 ac

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Body Style

    multipole-multiple actuator type

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.000 minimum at 200 pct all locations and 10.000 maximum at 200 pct all locations

  • Unpackaged Unit Weight

    6.500 ounces

  • Mounting Facility Type And Quantity

    4 clip

  • Switch Contact Arrangement

    single pole, double throw

  • Internal Trip Release Configuration

    series trip second location

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...