84110-004

Coils and Transformers

TRANSFORMER,POWER

84110-004

5950-01-301-2525

5950 - Coils and Transformers

Defense Electronics Supply Center

TRANSFORMER,POWER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Reliability Indicator

    not established

  • Frequency Rating

    380.0 hertz minimum single component and 420.0 hertz maximum

  • Input-Output Phase Relationship

    single phase to single phase single component

  • Body Outside Diameter

    0.510 inches maximum

  • Maximum Operating Temp

    130.0 deg celsius

  • Inclosure Type

    fully inclosed

  • Winding Tap Location

    center tap single component single secondary

  • Winding Operating Current

    13.0 milliamperes ac maximum single component single secondary

  • Unpackaged Unit Weight

    10.5 grams

  • Body Length

    0.500 inches maximum

  • Mounting Method

    terminal single group

  • Winding Function And Quantity

    1 primary single component and 1 secondary

  • Winding Power Rating

    0.8 volts-amperes single component single secondary

  • Winding Operating Voltage

    30.00 ac volts nominal single component single secondary

  • Special Features

    transformer has been designed for series or parallel operation

  • Terminal Type And Quantity

    5 wire lead

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...