366066-1
Coils and Transformers
TRANSFORMER,POWER
366066-1
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Cubic Measure (Non-Core)
37.6 cubic inches
-
Frequency Rating
380.0 hertz minimum single component and 420.0 hertz maximum single component
-
Winding Operating Voltage
150.00 ac volts nominal single component 1st secondary
-
Test Data Document
96214-366066 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Overall Width
3.600 inches maximum
-
Transformer Winding Connection Type
wye-delta
-
Winding Function And Quantity
1 primary single component and 2 secondary single component
-
Overall Height
2.550 inches maximum
-
Inclosure Type
fully inclosed
-
Winding Operating Current
2.0 amperes ac maximum single component 2nd secondary
-
Input-Output Phase Relationship
three phase to three phase single component
-
Winding Operating Voltage
187.00 ac volts minimum single component single primary and 205.00 ac volts maximum single component single primary
-
Reliability Indicator
not established
-
Winding Operating Voltage
60.00 ac volts nominal single component 2nd secondary
-
Winding Operating Current
2.5 amperes ac maximum single component 1st secondary
-
Mounting Method
terminal single group
-
Overall Length
4.100 inches maximum
-
Terminal Type And Quantity
10 tab, solder lug
-
Unpackaged Unit Weight (Non-Core)
69.000 ounces