DSF022
Coils and Transformers
TRANSFORMER,AUDIO FREQUENCY
DSF022
TRANSFORMER,AUDIO FREQUENCY
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Terminal Type And Quantity
7 wire lead
-
Maximum Transformer Power Rating
1.0 milliwatts single component
-
Frequency Rating
400.0 hertz minimum single component and 250.0 kilohertz maximum single component
-
Primary To Secondary Turn Ratio
1 to 1 single component
-
Impedance Rating In Ohms
500.0 nominal single component single secondary
-
Precious Material
gold
-
Features Provided
tinned wire leads
-
Winding Operating Current
2.0 milliamperes maximum of standard range b and better drop siding single component single primary
-
Winding Function And Quantity
1 primary single component and 1 secondary single component
-
Maximum Operating Temp
105.0 deg celsius
-
Frequency Response Tolerance In Decibels (Non-Core)
-3.0/+3.0 single component
-
Overall Diameter
0.350 inches maximum
-
Impedance Rating In Ohms
500.0 nominal single component single primary
-
Precious Material And Location
plated terminals gold
-
Reliability Indicator
not established
-
Winding Shielding Method
internal shield grounded to core and brought out to terminal single component
-
Mounting Method
terminal single group
-
Test Data Document
80064-2618756 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Inclosure Type
hermetically sealed
-
Winding Tap Location (Non-Core)
center tap single component single primary
-
Overall Length
0.370 inches maximum
-
Winding Tap Location (Non-Core)
center tap single component single secondary