CC887-2
Coils and Transformers
TRANSFORMER,POWER
CC887-2
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Height
3.220 inches minimum and 3.280 inches maximum
-
Thread Direction (Non-Core)
err-070
-
Body Width
2.970 inches minimum and 3.030 inches maximum
-
Winding Operating Voltage
150.00 ac volts nominal single component single primary
-
Terminal Type And Quantity
4 turret
-
Winding Operating Current
2.5 amperes dc nominal single component single secondary
-
Nominal Thread Size
0.190 inches single group
-
Winding Shielding Method
internal shield grounded to core single component
-
Maximum Operating Temp
130.0 deg celsius
-
Input-Output Phase Relationship
single phase to single phase single component
-
Center To Center Distance Between Mounting Facilities Parallel To Length
2.735 inches minimum single mounting facility single center group and 2.765 inches maximum single mounting facility single center group
-
Thread Class (Non-Core)
err-070
-
Frequency Rating
400.0 hertz nominal single component
-
Reliability Indicator
not established
-
Winding Function And Quantity
1 primary single component and 1 secondary single component
-
Inclosure Type
fully inclosed
-
Thread Series Designator
unf single group
-
Mounting Method
threaded stud single group
-
Center To Center Distance Between Mounting Facilities Parallel To Width
2.110 inches minimum single mounting facility single center group and 2.140 inches maximum single mounting facility single center group
-
Body Length
3.720 inches minimum and 3.780 inches maximum
-
Mounting Facility Quantity
4 single group