60225-364

Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

60225-364

5915-01-302-5680

5915 - Filters and Networks

Bae Systems Integrated Defense

FILTER,RADIO FREQUENCY INTERFERENCE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Overall Height

    0.965 inches maximum

  • Vibration Resistance Range In Hertz

    20.0/ 2000.0

  • Operating Temp Range

    -54.0/+125.0 deg celsius

  • Source Impedance Rating Per Function

    50.0 ohms 2nd radio interference .

  • Source Impedance Rating Per Function

    50.0 ohms 5th radio interference .

  • Load Impedance Per Function

    50.0 ohms 1st radio interference .

  • Load Impedance Per Function

    50.0 ohms 2nd radio interference .

  • Load Impedance Per Function

    50.0 ohms 6th radio interference .

  • Power Line Frequency Rating Per Function In Hertz

    400.0 1st radio interference .

  • Power Line Frequency Rating Per Function In Hertz

    400.0 2nd radio interference .

  • Power Line Frequency Rating Per Function In Hertz

    400.0 3rd radio interference .

  • Power Line Frequency Rating Per Function In Hertz

    400.0 4th radio interference .

  • Power Line Frequency Rating Per Function In Hertz

    400.0 5th radio interference .

  • Operating Current Rating Per Function In Amps

    3.0 1st radio interference .

  • Operating Current Rating Per Function In Amps

    3.0 4th radio interference .

  • Operating Current Rating Per Function In Amps

    3.0 5th radio interference .

  • Principal Circuitry Type Per Function

    inductance-capacitance 2nd radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 6th radio interference

  • Functional Terminal Type And Quantity

    1 connector, plug input .

  • Operating Voltage Rating And Type Per Function

    125.0 volts ac 2nd radio interference and 200.0 volts dc 2nd radio interference

  • Operating Voltage Rating And Type Per Function

    125.0 volts ac 5th radio interference and 200.0 volts dc 5th radio interference

  • Operating Voltage Rating And Type Per Function

    125.0 volts ac 6th radio interference and 200.0 volts dc 6th radio interference

  • Operating Voltage Rating And Type Per Function

    50.0 volts ac 1st radio interference and 100.0 volts dc 1st radio interference .

  • Special Features

    50 functions; 48 filtered contacts and 2 power contacts

  • Style Designator

    45 filter connector

  • Principal Circuitry Type Per Function

    inductance-capacitance 3rd radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 4th radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 5th radio interference

  • Inclosure Type

    encased

  • Mounting Facility Type And Quantity

    2 unthreaded hole

  • Functional Terminal Type And Quantity

    50 friction w/grounding strap and pin output .

  • ~1

    .

  • Operating Voltage Rating And Type Per Function

    125.0 volts ac 3rd radio interference and 200.0 volts dc 3rd radio interference

  • Operating Voltage Rating And Type Per Function

    50.0 volts ac 4th radio interference and 100.0 volts dc 4th radio interference .

  • Overall Length

    2.620 inches minimum and 2.658 inches maximum

  • Overall Width

    0.590 inches minimum and 0.720 inches maximum

  • Unthreaded Mounting Hole Diameter

    0.115 inches minimum and 0.125 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.401 inches minimum and 2.411 inches maximum

  • Source Impedance Rating Per Function

    50.0 ohms 1st radio interference .

  • Source Impedance Rating Per Function

    50.0 ohms 3rd radio interference .

  • Source Impedance Rating Per Function

    50.0 ohms 4th radio interference .

  • Source Impedance Rating Per Function

    50.0 ohms 6th radio interference .

  • Load Impedance Per Function

    50.0 ohms 3rd radio interference .

  • Load Impedance Per Function

    50.0 ohms 4th radio interference .

  • Load Impedance Per Function

    50.0 ohms 5th radio interference .

  • Power Line Frequency Rating Per Function In Hertz

    400.0 6th radio interference .

  • Operating Current Rating Per Function In Amps

    3.0 2nd radio interference .

  • Operating Current Rating Per Function In Amps

    3.0 3rd radio interference .

  • Operating Current Rating Per Function In Amps

    3.0 6th radio interference .

  • Principal Circuitry Type Per Function

    inductance-capacitance 1st radio interference

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.