80516-2
Circuit Breakers
CIRCUIT BREAKER
80516-2
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac single location
-
Terminal Type And Quantity
2 tab w/screw
-
Body Length
2.260 inches maximum
-
Body Width
2.200 inches maximum
-
Trip Delay Time In Seconds Per Rated Continuous Current
20.000 minimum at 200 pct single location and 52.000 maximum at 200 pct single location
-
Case Material
plastic
-
Unpackaged Unit Weight
0.650 pounds
-
Fragility Factor
moderately rugged
-
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
-
Special Handling Feature
magnetic
-
Thread Series Designator
unc
-
Maximum Continuous Load Current Rating Per Pole
25.0 amperes ac single location
-
Reset Method
manual
-
Actuator Position Designation
at pole one
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
Manual Actuator Type And Quantity
1 push button
-
Mounting Facility Type And Quantity
2 threaded hole
-
Thread Quantity Per Inch
32
-
Circuit Protection Type
overcurrent single location
-
Inclosure Protection Type For Which Designed
shock resistant and corrosion resistant and fungus proof and humidity resistant and dusttight and vibration resistant and sandtight and explosion proof
-
Pole Quantity
1
-
Body Style
multipole-single actuator type
-
Mounting Surface To Terminal End Distance
2.470 inches nominal
-
Nominal Thread Size
0.138 inches
-
Trip Release Method
thermal-magnetic single location
-
Center To Center Distance Between Terminals Parallel To Length
1.190 inches nominal
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac single location
-
Trip Release Characteristic
time delay single location
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location
-
Main Contact Tripping Mechanism Type
trip free
-
Arc Quenching Method
magnetic blowout
-
Frequency In Hertz
400.0 single location
-
Bushing Length
0.235 inches minimum and 0.250 inches maximum