55898-90102-1

Circuit Breakers

CIRCUIT BREAKER

55898-90102-1

5925-01-304-5788

5925 - Circuit Breakers

Aai Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.000 minimum at 200 pct single location and 15.000 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    dustproof

  • Frequency In Hertz

    50.0 single location or 60.0

  • Thread Series Designator

    unef

  • Bushing Length

    0.390 inches minimum and 0.410 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.110 inches minimum and 1.130 inches maximum

  • Mounting Surface To Terminal End Distance

    1.950 inches minimum and 1.970 inches maximum

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    magnetic single location

  • Trip Release Characteristic

    time delay single location

  • Manual Actuator Type And Quantity

    1 push-pull

  • Nominal Thread Size

    0.375 inches

  • Terminal Type And Quantity

    2 quick disconnect, male

  • Body Style

    1a single pole type

  • Body Length

    1.365 inches minimum and 1.385 inches maximum

  • Body Width

    0.670 inches minimum and 0.690 inches maximum

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    1

  • Arc Quenching Method

    magnetic blowout

  • Maximum Continuous Load Current Rating Per Pole

    3.0 amperes ac single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Internal Trip Release Configuration

    series trip single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...