Technical Characteristics

  • Body Width

    2.250 inches maximum

  • Fragility Factor

    moderately rugged

  • Switch Terminal Type

    tab, solder lug

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.735 inches minimum and 0.765 inches maximum

  • Switch Voltage Rating And Type In Volts

    250.0 ac

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Inclosure Protection Type For Which Designed

    humidity resistant and salt spray proof

  • Reset Method

    manual

  • Storage Type

    general purpose warehouse

  • Switch Current Rating And Type In Amps

    10.0 ac

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.130 minimum at 200 pct all locations and 1.300 maximum at 200 pct all locations

  • Thread Quantity Per Inch

    32

  • Boss Height

    0.135 inches minimum and 0.165 inches maximum

  • Trip Release Method

    magnetic all locations

  • Body Style

    multipole-multiple actuator type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Switch Contact Arrangement

    single pole, double throw

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Nominal Thread Size

    0.138 inches

  • Frequency In Hertz

    60.0 all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.735 inches minimum and 0.765 inches maximum

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Center To Center Distance Between Terminals Parallel To Length

    2.055 inches minimum and 2.065 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    3.5 amperes ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Mounting Surface To Terminal End Distance

    2.915 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.055 inches minimum and 2.065 inches maximum

  • Body Length

    2.480 inches minimum and 2.500 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    480.0 ac all locations

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Manual Actuator Type And Quantity

    3 toggle

  • Switch Location And Position Designation

    internal at pole one

  • Case Material

    plastic

  • Terminal Type And Quantity

    6 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...