DDT50SP2-AAV

Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

DDT50SP2-AAV

5915-01-305-9307

5915 - Filters and Networks

Itt Industries Limited Itt Cannon

FILTER,RADIO FREQUENCY INTERFERENCE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Principal Circuitry Type Per Function

    inductance-capacitance 2nd radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 6th radio interference

  • Functional Terminal Type And Quantity

    1 connector, receptacle input

  • Functional Terminal Type And Quantity

    50 friction w/grounding strap and pin output

  • Operating Voltage Rating And Type Per Function

    50.0 volts ac 4th radio interference and 100.0 volts dc 4th radio interference

  • Operating Voltage Rating And Type Per Function

    50.0 volts ac 5th radio interference and 100.0 volts dc 5th radio interference

  • Special Features

    50 filtered contacts

  • Style Designator

    45 filter connector

  • Overall Length

    2.620 inches minimum and 2.658 inches maximum

  • Overall Width

    0.590 inches minimum and 0.720 inches maximum

  • Unthreaded Mounting Hole Diameter

    0.115 inches minimum and 0.125 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.401 inches minimum and 2.411 inches maximum

  • Source Impedance Rating Per Function

    50.0 ohms 1st radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 2nd radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 3rd radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 4th radio interference

  • Load Impedance Per Function

    50.0 ohms 1st radio interference

  • Load Impedance Per Function

    50.0 ohms 3rd radio interference

  • Load Impedance Per Function

    50.0 ohms 5th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    60.0 1st radio interference

  • Power Line Frequency Rating Per Function In Hertz

    60.0 5th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    60.0 6th radio interference

  • Operating Current Rating Per Function In Amps

    60.0 2nd radio interference

  • Operating Current Rating Per Function In Amps

    60.0 4th radio interference

  • Operating Current Rating Per Function In Amps

    60.0 5th radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 1st radio interference

  • Overall Height

    0.965 inches maximum

  • Vibration Resistance Range In Hertz

    20.0 to 2000.0

  • Operating Temp Range

    -55.0 to 125.0 deg celsius

  • Source Impedance Rating Per Function

    50.0 ohms 5th radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 6th radio interference

  • Load Impedance Per Function

    50.0 ohms 2nd radio interference

  • Load Impedance Per Function

    50.0 ohms 4th radio interference

  • Load Impedance Per Function

    50.0 ohms 6th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    60.0 2nd radio interference

  • Power Line Frequency Rating Per Function In Hertz

    60.0 3rd radio interference

  • Power Line Frequency Rating Per Function In Hertz

    60.0 4th radio interference

  • Operating Current Rating Per Function In Amps

    60.0 1st radio interference

  • Operating Current Rating Per Function In Amps

    60.0 3rd radio interference

  • Operating Current Rating Per Function In Amps

    60.0 6th radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 3rd radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 4th radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 5th radio interference

  • Inclosure Type

    encased

  • Mounting Facility Type And Quantity

    2 unthreaded hole

  • Features Provided

    shock resistant

  • Operating Voltage Rating And Type Per Function

    50.0 volts ac 1st radio interference and 100.0 volts dc 1st radio interference

  • Operating Voltage Rating And Type Per Function

    50.0 volts ac 2nd radio interference and 100.0 volts dc 2nd radio interference

  • Operating Voltage Rating And Type Per Function

    50.0 volts ac 3rd radio interference and 100.0 volts dc 3rd radio interference

  • Operating Voltage Rating And Type Per Function

    50.0 volts ac 6th radio interference and 100.0 volts dc 6th radio interference

  • Body Material

    metal

  • Maximum Dielectric Withstanding Dc Voltage

    300.0 volts at sea level

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...