GJ3-Z67-1

Circuit Breakers

CIRCUIT BREAKER

GJ3-Z67-1

5925-01-306-3521

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Frequency In Hertz

    50.0 all locations or 60.0

  • Body Width

    4.500 inches nominal

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Width

    1.500 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.638 inches minimum and 4.668 inches maximum

  • Fragility Factor

    moderately rugged

  • Arc Quenching Method

    magnetic blowout

  • Special Handling Feature

    magnetic

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac first location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac third location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    18000.0 ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Trip Release Characteristic

    time delay all locations

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Internal Trip Release Configuration

    series trip second location

  • Internal Trip Release Configuration

    series trip third location

  • Internal Trip Release Configuration

    shunt trip first location

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Body Style

    5c multipole-multiple actuator type

  • Body Length

    7.125 inches nominal

  • Body Height

    2.968 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    2.797 inches minimum and 2.827 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.500 inches nominal

  • Boss Height

    0.218 inches nominal

  • Pole Quantity

    3

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    125.0 amperes ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac second location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Manual Actuator Type And Quantity

    3 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Nominal Thread Size

    0.190 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct all locations and 100.500 maximum at 200 pct

  • Thread Series Designator

    unf

  • Terminal Type And Quantity

    6 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...