CVH-3-30-1-M/M
Filters and Networks
FILTER,BAND PASS
CVH-3-30-1-M/M
FILTER,BAND PASS
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Overall Length
4.390 inches nominal
-
Body Width
1.120 inches nominal
-
Body Height
3.880 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.010 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches nominal
-
Iii End Item Identification
training set,electronic warfare an/mst-t1v
-
Reference Frequency Per Function
30.0 megahertz blank
-
Source Impedance Rating Per Function
50.0 ohms blank
-
Iii Input Terminal Manufacturer Code
50140
-
Mounting Facility Type And Quantity
4 unthreaded hole
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 blank
-
Functional Terminal Type And Quantity
1 connector, receptacle input
-
Functional Terminal Type And Quantity
1 connector, receptacle output
-
Iii Specified Frequencies Of Discrimination Per Function
28.00 megahertz blank and
-
Iii Specified Frequencies Of Discrimination Per Function
29.50 megahertz blank and
-
Iii Specified Frequencies Of Discrimination Per Function
30.50 megahertz blank and
-
Iii Body Material
metal
-
Frequency Band Width Per Function
30.50 megahertz blank
-
Iii Discrimination At Specified Frequencies Per Function In Decibels
3.0 maximum blank and
-
Iii Discrimination At Specified Frequencies Per Function In Decibels
30.0 minimum blank
-
Iii Discrimination At Specified Frequencies Per Function In Decibels
30.0 minimum blank and
-
Style Designator
5 rectangular terminal/terminals on opposite surfaces
-
Body Length
3.630 inches nominal
-
Unthreaded Mounting Hole Diameter
0.160 inches nominal
-
Iii Operating Temp Range
-20.0 to 50.0 deg celsius
-
Load Impedance Per Function
50.0 ohms blank
-
Iii Principal Circuitry Type Per Function
inductance-capacitance blank
-
Iii Input Terminal Identification
sma-receptacle
-
Iii Output Terminal Manufacturer Code
50140
-
Iii Output Terminal Identification
sma-receptacle
-
Voltage Standing Wave Ratio Per Function
1.5 blank
-
Inclosure Type
encased
-
Iii Specified Frequencies Of Discrimination Per Function
32.00 megahertz blank
-
Frequency Band Width Per Function
29.50 megahertz blank and
-
Voltage Standing Wave Ratio Frequency Limits Per Function
29.5 megahertz blank and
-
Voltage Standing Wave Ratio Frequency Limits Per Function
30.5 megahertz blank