TD3A

Resistors

RESISTOR,THERMAL

TD3A

5905-01-307-7615

5905 - Resistors

Honeywell International Inc.

RESISTOR,THERMAL

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Reliability Indicator

    not established

  • Maximum Operating Temp

    150.0 deg celsius

  • Power Dissipation Constant In Milliwatts Per Deg Celsius

    0.04

  • Zero Power Temp Coefficient Of Resistance In Percent Per Deg Celsius

    2.50

  • Temp Points For Resistance Readings At Zero Power

    110.0 deg celsius 8th resistance-temperature point

  • Temp Points For Resistance Readings At Zero Power

    130.0 deg celsius 9th resistance-temperature point

  • Temp Points For Resistance Readings At Zero Power

    150.0 deg celsius 10th resistance-temperature point

  • Temp Points For Resistance Readings At Zero Power

    70.0 deg celsius 6th resistance-temperature point

  • Zero Power Resistance At Specified Temp

    2.74 kilohms 8th resistance-temperature point

  • Zero Power Resistance At Specified Temp

    2.924 kilohms 9th resistance-temperature point

  • Resistance Tolerance At A Specified Temp In Percent

    -25.0/ 25.0

  • Resistance Tolerance At A Specified Temp In Percent

    -7.0/ 7.0

  • Resistance Tolerance At A Specified Temp In Percent

    -8.0/ 8.0

  • Zero Power Resistance

    2.000 kilohms

  • Reference Temp In Deg Celsius

    20.0

  • ~1

    sensing surface temperatures

  • Fsc Application Data

    electrical and electronic equipment components

  • Terminal Type And Quantity

    3 wire lead

  • Special Features

    linear temperature sensitivity; air or liquid temperature sensing; designed for

  • Zero Power Resistance Tolerance In Percent At Reference Temp

    -5.0/ 5.0

  • Inclosure Type

    encapsulated

  • End Item Identification

    gcn/ded

  • Resistance Tolerance At A Specified Temp In Percent

    -6.0/ 6.0

  • Resistance Tolerance At A Specified Temp In Percent

    -22.0/ 22.0

  • Resistance Tolerance At A Specified Temp In Percent

    -18.0/ 18.0

  • Resistance Tolerance At A Specified Temp In Percent

    -14.0/ 14.0

  • Resistance Tolerance At A Specified Temp In Percent

    -10.0/ 10.0

  • Zero Power Resistance At Specified Temp

    3.114 kilohms 10th resistance-temperature point

  • Zero Power Resistance At Specified Temp

    2.564 kilohms 7th resistance-temperature point

  • Zero Power Resistance At Specified Temp

    2.394 kilohms 6th resistance-temperature point

  • Zero Power Resistance At Specified Temp

    2.231 kilohms 5th resistance-temperature point

  • Zero Power Resistance At Specified Temp

    1.855 kilohms 3rd resistance-temperature point

  • Temp Points For Resistance Readings At Zero Power

    90.0 deg celsius 7th resistance-temperature point

  • Temp Points For Resistance Readings At Zero Power

    50.0 deg celsius 5th resistance-temperature point

  • Temp Points For Resistance Readings At Zero Power

    -40.0 deg celsius 1st resistance-temperature point

  • Temp Points For Resistance Readings At Zero Power

    30.0 deg celsius 4th resistance-temperature point

  • Temp Points For Resistance Readings At Zero Power

    -20.0 deg celsius 2nd resistance-temperature point

  • Temp Points For Resistance Readings At Zero Power

    0.0 deg celsius 3rd resistance-temperature point

  • Thermal Time Constant In Seconds

    75.0

  • Zero Power Resistance At Specified Temp

    1.716 kilohms 2nd resistance-temperature point

  • Zero Power Resistance At Specified Temp

    1.584 kilohms 1st resistance-temperature point

  • Zero Power Resistance At Specified Temp

    2.075 kilohms 4th resistance-temperature point

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...