ET-94200

Circuit Breakers

CIRCUIT BREAKER

ET-94200

5925-01-311-8328

5925 - Circuit Breakers

Spd Electrical Systems Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Inclosure Protection Type For Which Designed

    fungus proof and general purpose

  • Trip Release Characteristic

    instantaneous all locations

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Reset Method

    manual

  • Auxiliary Switch Function And Quantity

    2 alarm

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.484 inches minimum and 1.516 inches maximum

  • Storage Type

    general purpose warehouse

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Center To Center Distance Between Terminals Parallel To Length

    5.109 inches minimum and 5.141 inches maximum

  • Actuator Function

    trip-reset

  • Switch Terminal Type

    wire lead

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Special Features

    includes 3 tulip connectors for line side and 3 tulip connectors for load side

  • Actuator Position Designation

    at pole two

  • Switch Contact Arrangement

    single pole, double throw

  • Body Style

    multipole-single actuator type

  • Body Width

    4.484 inches minimum and 4.516 inches maximum

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Terminal Type And Quantity

    6 compression

  • Mounting Surface To Terminal End Distance

    3.984 inches minimum and 4.015 inches maximum

  • Switch Location And Position Designation

    internal between pole two and three

  • Unthreaded Mounting Hole Diameter

    0.164 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    15000.0 ac all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.578 inches minimum and 4.610 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    1.484 inches minimum and 1.516 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac all locations

  • Body Length

    5.984 inches minimum and 6.015 inches maximum

  • Boss Height

    0.203 inches minimum and 0.235 inches maximum

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...