1214C3931
Coils and Transformers
TRANSFORMER,RADIO FREQUENCY
1214C3931
TRANSFORMER,RADIO FREQUENCY
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Coil Form Type
solid single component
-
Winding Conductor Size
0.01003 inches american wire gage single component 2nd secondary
-
Winding Conductor Size
0.01594 inches american wire gage single component 4th secondary
-
Body Length
0.715 inches maximum
-
Winding Function And Quantity
2 primary single component and 6 secondary single component
-
Mounting Facility Quantity
1 single group
-
Winding Conductor Size
0.01594 inches american wire gage single component all primary
-
Rating Method
electrical single component 1st primary and winding turns single component 1st primary
-
Reliability Indicator
not established
-
Turn Quantity
6 single component 4th secondary
-
Terminal Type And Quantity
16 wire lead
-
Frequency Rating
50.0 kilohertz nominal single component
-
Turn Quantity
34 single component all primary
-
Features Provided
tinned wire leads
-
Body Outside Diameter
1.070 inches maximum
-
Rating Method
winding turns single component all secondary
-
Turn Quantity
17-1/2 single component 1st secondary
-
Inclosure Type
fully inclosed
-
Mounting Hole Diameter
0.213 inches minimum single group and 0.223 inches maximum single group
-
Rating Method
winding turns single component 2nd primary
-
Mounting Method
unthreaded hole single group
-
Cubic Measure (Non-Core)
2.57 cubic inches
-
Winding Conductor Size
0.01003 inches american wire gage single component 1st secondary
-
Turn Quantity
6 single component 3rd secondary
-
Inductance Rating
1156.00 microhenries nominal single component 1st primary
-
Turn Quantity
17-1/2 single component 2nd secondary
-
Special Features
2primary windings; 6secondary windings
-
Winding Conductor Size
0.01594 inches american wire gage single component 3rd secondary