AA1-B0-10-630-2G1-B
Circuit Breakers
CIRCUIT BREAKER
AA1-B0-10-630-2G1-B
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Fragility Factor
moderately rugged
-
Trip Release Method
magnetic single location
-
Special Handling Feature
magnetic
-
Thread Series Designator
unc
-
Unpackaged Unit Weight
65.0 grams
-
Reset Method
manual
-
Actuator Position Designation
at pole one
-
Body Length
1.990 inches minimum and 2.010 inches maximum
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
Mounting Facility Type And Quantity
2 threaded hole
-
Thread Quantity Per Inch
32
-
Circuit Protection Type
overcurrent single location
-
Boss Height
0.120 inches minimum and 0.140 inches maximum
-
Pole Quantity
1
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.650 inches minimum and 1.670 inches maximum
-
Inclosure Protection Type For Which Designed
shock resistant and vibration resistant and moisture resistant and salt spray proof
-
Manual Actuator Type And Quantity
1 toggle
-
Internal Trip Release Configuration
series trip single location
-
Nominal Thread Size
0.138 inches
-
Mounting Surface To Terminal End Distance
1.630 inches minimum and 1.650 inches maximum
-
Body Width
0.755 inches maximum
-
Main Contact Tripping Mechanism Type
trip free
-
Maximum Continuous Load Current Rating Per Pole
30.0 amperes dc single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2500.0 dc single location
-
Terminal Type And Quantity
2 tab, solder lug
-
Body Style
single pole type
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 single location
-
Trip Release Characteristic
instantaneous single location
-
Operating Voltage Type And Rating Per Pole In Volts
32.0 dc single location
-
Center To Center Distance Between Terminals Parallel To Length
1.550 inches minimum and 1.570 inches maximum
-
Case Material
plastic