970-002-150
Circuit Breakers
CIRCUIT BREAKER
970-002-150
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Bushing Length
0.235 inches minimum and 0.250 inches maximum
-
Manual Actuator Type And Quantity
3 push button
-
Frequency In Hertz
400.0 all locations
-
Maximum Continuous Load Current Rating Per Pole
150.0 amperes ac all locations and 150.0 amperes dc all locations
-
Terminal Type And Quantity
6 tab w/screw
-
Center To Center Distance Between Terminals Parallel To Length
1.406 inches minimum and 1.468 inches maximum
-
Case Material
plastic
-
Trip Release Method
thermal all locations
-
Fragility Factor
moderately rugged
-
Switch Terminal Type
tab, solder lug
-
Mounting Facility Type And Quantity
6 unthreaded hole
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Body Width
2.189 inches maximum
-
Actuator Position Designation
at each pole
-
Reset Method
manual
-
Mounting Surface To Terminal End Distance
2.219 inches minimum and 2.249 inches maximum
-
Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2500.0 ac all locations and 3000.0 dc all locations
-
Auxiliary Switch Function And Quantity
3 alarm
-
External Actuator Linkage Arrangement
one, two, and three linked
-
Internal Trip Release Configuration
series trip all locations
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac all locations and 30.0 dc all locations
-
Inclosure Protection Type For Which Designed
vibration resistant and shock resistant
-
Center To Center Distance Between Terminals Parallel To Width
1.045 inches minimum and 1.075 inches maximum
-
Body Style
multipole-multiple actuator type
-
Switch Contact Arrangement
single pole, double throw
-
Body Length
2.406 inches minimum and 2.468 inches maximum
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal all locations
-
Unthreaded Mounting Hole Diameter
0.140 inches nominal
-
Main Contact Tripping Mechanism Type
trip free
-
Trip Delay Time In Seconds Per Rated Continuous Current
15.000 minimum at 200 pct all locations and 70.000 maximum at 200 pct all locations
-
Unpackaged Unit Weight
130.0 grams
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 all locations
-
Switch Location And Position Designation
internal at each pole
-
Switch Voltage Rating And Type In Volts
120.0 ac and 28.0 dc
-
Switch Current Rating And Type In Amps
100.0 ac and 100.0 dc