M83536/10-022L
Relays and Solenoids
RELAY,ELECTROMAGNETIC
M83536/10-022L
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Fragility Factor
moderately rugged
-
Specification/Standard Data
81349--83536/10 government specification
-
Nominal Operating Current Rating And Type
110.0 milliamperes dc single winding
-
Main Contact Load Current Rating At Maximum Rated Voltage
4.0 amperes ac motor load and 4.0 amperes dc motor load
-
Overall Height
1.010 inches maximum
-
Storage Type
general purpose warehouse
-
Criticality Code Justification
feat
-
Time Delay
0.01 seconds maximum fixed operate and release time
-
Nonpile-Up Main Contact Arrangement
2 pole, double throw, one position momentary
-
Cubic Measure
0.543 cubic inches
-
Environmental Protection
hermetic
-
Mounting Slot Width
0.150 inches nominal single mounting facility
-
Winding Dc Resistance Rating
320.0 ohms nominal single winding
-
Arc Quenching Method
air
-
Mounting Facility Type And Quantity
2 slotted hole single mounting facility
-
Winding Quantity
1
-
Case Material
metal
-
Main Contact Load Current Rating At Maximum Rated Voltage
2.0 amperes ac lamp load and 2.0 amperes dc lamp load
-
Overall Length
1.025 inches maximum
-
Overall Width
0.525 inches maximum
-
Terminal Type And Quantity
8 pin all functions
-
Main Contact Maximum Voltage Rating In Volts
200.0 ac and 28.0 dc
-
Purpose For Which Designed
general
-
Test Data Document
81349-mil-r-83536 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
~1
data on certain environmental and performanc
-
Operating Voltage Rating And Type At Specified Temp
28.0 volts dc 25 deg celsius single winding
-
Coil Quantity
1
-
Center To Center Distance Between Mounting Facilities Parallel To Length
1.421 inches nominal single mounting facility
-
Main Contact Load Current Rating At Maximum Rated Voltage
8.0 amperes ac inductive load and 8.0 amperes dc inductive load
-
Duty Type
continuous
-
Mounting Facility Pattern
in-line single mounting facility
-
Special Features
failure rate: 1.0 percent per 10,000 cycles
-
Main Contact Load Current Rating At Maximum Rated Voltage
10.0 amperes ac resistive load and 10.0 amperes dc resistive load