T4-0134

Filters and Networks

FILTER,BAND PASS

T4-0134

5915-01-316-1740

5915 - Filters and Networks

Lockheed Martin Corp

FILTER,BAND PASS

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Overall Length

    2.410 inches nominal

  • Body Length

    1.650 inches nominal

  • Body Width

    0.490 inches nominal

  • Body Height

    0.390 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.530 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.370 inches nominal

  • End Item Identification

    training set,countermeasures signals an/msr-t4

  • Source Impedance Rating Per Function

    50.0 ohms blank

  • Load Impedance Per Function

    50.0 ohms blank

  • Output Terminal Identification

    sma-receptacle

  • Voltage Standing Wave Ratio Per Function

    1.5 blank

  • Mounting Facility Screw Thread Series Designator

    unf

  • Inclosure Type

    encased

  • Insertion Loss At Reference Frequency Per Function In Decibels

    4.0 blank

  • Specified Frequencies Of Discrimination Per Function

    970.00 megahertz blank and 1.055 gigahertz blank and 1.065 gigahertz blank and 1

  • Nominal Thread Size

    0.060 inches

  • Operating Temp Range

    +0.0/+50.0 deg celsius

  • Reference Frequency Per Function

    1.06 gigahertz blank

  • Principal Circuitry Type Per Function

    inductance-capacitance blank

  • Input Terminal Manufacturer Code

    56216

  • Input Terminal Identification

    sma-receptacle

  • Output Terminal Manufacturer Code

    56216

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Functional Terminal Type And Quantity

    1 connector, receptacle input .

  • Functional Terminal Type And Quantity

    1 connector, receptacle output .

  • ~1

    .15 gigahertz blank

  • Body Material

    aluminum

  • Frequency Band Width Per Function

    1.055 gigahertz blank and 1.065 gigahertz blank

  • Discrimination At Specified Frequencies Per Function In Decibels

    1.0 minimum blank and 60.0 maximum blank

  • Voltage Standing Wave Ratio Frequency Limits Per Function

    1.055 gigahertz blank and 1.065 gigahertz blank

  • Style Designator

    5 rectangular terminal/terminals on opposite surfaces

  • Body Surface Treatment

    nickel

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...