CD3-C3-A-50-240-3

Circuit Breakers

CIRCUIT BREAKER

CD3-C3-A-50-240-3

5925-01-317-9323

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Center To Center Distance Between Terminals Parallel To Length

    3.537 inches minimum and 3.557 inches maximum

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Nominal Thread Size

    0.138 inches

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.740 inches minimum and 2.760 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    1.016 inches minimum and 1.036 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.280 minimum at 200 pct all locations and 1.000 maximum at 200 pct all locations

  • Frequency In Hertz

    400.0 all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 ac all locations

  • Manual Actuator Type And Quantity

    3 toggle

  • Inclosure Protection Type For Which Designed

    dustproof and fungus resistant

  • Body Width

    3.108 inches maximum

  • Case Material

    plastic

  • Terminal Type And Quantity

    6 threaded stud

  • Mounting Surface To Terminal End Distance

    2.599 inches minimum and 2.619 inches maximum

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.016 inches minimum and 1.036 inches maximum

  • Boss Height

    0.209 inches minimum and 0.229 inches maximum

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Body Style

    multipole-multiple actuator type

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac all locations

  • Body Length

    5.790 inches minimum and 5.810 inches maximum

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...