TEC36150

Circuit Breakers

CIRCUIT BREAKER

TEC36150

5925-01-317-9325

5925 - Circuit Breakers

General Electric Co

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Case Material

    plastic

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac all locations

  • Body Height

    3.375 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    0.687 inches nominal

  • Body Length

    8.187 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.375 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    25000.0 ac all locations

  • Maximum Continuous Load Current Rating Per Pole

    150.0 amperes ac all locations

  • Boss Height

    0.125 inches nominal

  • Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Main Contact Tripping Mechanism Type

    trip free

  • Terminal Type And Quantity

    6 compression

  • Frequency In Hertz

    60.0 all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Body Style

    multipole-single actuator type

  • Actuator Position Designation

    at pole two

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Release Method

    magnetic all locations

  • Adjustable Trip Setting Current Range Per Pole In Amps

    +600.0/+2700.0 ac all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.874 inches nominal

  • Internal Trip Release Configuration

    series trip all locations

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

  • Unthreaded Mounting Hole Diameter

    0.196 inches nominal

  • Features Provided

    adjustable trip release

  • Reset Method

    manual

  • Body Width

    4.125 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    4.874 inches nominal

  • Inclosure Protection Type For Which Designed

    dustproof

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

  • Trip Release Characteristic

    instantaneous all locations

  • Fragility Factor

    moderately rugged

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...