HMCP150T4

Circuit Breakers

CIRCUIT BREAKER

HMCP150T4

5925-01-317-9327

5925 - Circuit Breakers

Eaton Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac all locations and 250.0 dc all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.500 inches nominal

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Center To Center Distance Between Terminals Parallel To Width

    1.375 inches nominal

  • Thread Quantity Per Inch

    32

  • Packaged Unit Weight

    4.500 pounds

  • Trip Release Method

    magnetic all locations

  • Center To Center Distance Between Terminals Parallel To Length

    4.500 inches nominal

  • Actuator Position Designation

    at pole two

  • Body Height

    3.500 inches nominal

  • Body Style

    multipole-single actuator type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Terminal Type And Quantity

    1 compression

  • Arc Quenching Method

    magnetic blowout

  • Nominal Thread Size

    0.164 inches

  • Boss Height

    0.125 inches nominal

  • Inclosure Protection Type For Which Designed

    general purpose

  • Frequency In Hertz

    50.0 all locations or 60.0 all locations

  • Body Length

    6.000 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.375 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    150.0 amperes ac all locations and 150.0 amperes dc all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    25000.0 ac all locations and 10000.0 dc all locations

  • Case Material

    plastic

  • Fragility Factor

    moderately rugged

  • Trip Release Characteristic

    instantaneous all locations

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Thread Series Designator

    unc

  • Body Width

    4.125 inches nominal

  • Adjustable Trip Setting Current Range Per Pole In Amps

    +450.0/+1500.0 ac all locations and +450.0/+1500.0 dc all locations

  • Reset Method

    manual

  • Features Provided

    adjustable trip release

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.