APGN11-1REC4-41-501
Circuit Breakers
CIRCUIT BREAKER
APGN11-1REC4-41-501
Sensata Technologies Maryland Inc
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Thread Series Designator
un
-
Switch Terminal Type
quick disconnect, male
-
Body Width
1.500 inches nominal
-
Switch Location And Position Designation
internal at pole one
-
Auxiliary Switch Function And Quantity
1 control
-
~1
and 0.400 maximum at 400 pct all locations an
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.004 minimum at 800 pct all locations and 0.250 maximum at 600 pct all locations and 0.006 minimum at 600 pct all locations and 0.020 minimum at 400 pct all locations and 0.100 maximum at 800 pct all locations and 0.004 minimum at 1000 pct all locations
-
Inclosure Protection Type For Which Designed
corrosion resistant and shock resistant and moisture resistant and vibration resistant
-
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
-
Circuit Protection Type
overcurrent all locations
-
Terminal Type And Quantity
10 quick disconnect, male
-
Pole Quantity
2
-
Reset Method
manual
-
Nominal Thread Size
0.500 inches
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Trip Release Characteristic
time delay all locations
-
Body Length
2.000 inches nominal
-
Thread Quantity Per Inch
32
-
Trip Release Method
magnetic-hydraulic all locations
-
Body Style
multipole-single actuator type
-
Manual Actuator Type And Quantity
1 toggle
-
Main Contact Tripping Mechanism Type
trip free
-
Internal Trip Release Configuration
series trip w/auxiliary load terminal all locations
-
Mounting Surface To Terminal End Distance
2.200 inches nominal
-
Center To Center Distance Between Terminals Parallel To Length
1.530 inches nominal
-
Maximum Continuous Load Current Rating Per Pole
0.5 amperes ac all locations
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
-
Frequency In Hertz
400.0 all locations
-
Bushing Length
0.495 inches nominal