APGN-11-1REC4-65-172

Circuit Breakers

CIRCUIT BREAKER

APGN-11-1REC4-65-172

5925-01-317-9967

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Special Handling Feature

    magnetic

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Reset Method

    manual

  • Nominal Thread Size

    0.500 inches

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Body Length

    2.000 inches nominal

  • Internal Trip Release Configuration

    series trip all locations

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic-hydraulic all locations

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 30.0 dc

  • Actuator Position Designation

    at pole two

  • Switch Contact Arrangement

    single pole, double throw

  • Nonturn Device Location

    at 3 oclock and at 9 oclock

  • Nonturn Device Diameter

    0.151 inches minimum and 0.161 inches maximum

  • Thread Pitch Diameters

    +0.4752/+0.4787 inches

  • Body Style

    multipole-single actuator type

  • Unpackaged Unit Weight

    6.000 ounces

  • ~1

    and 12.000 maximum at 200 pct all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    3.000 maximum at 400 pct all locations and 0.030 minimum at 800 pct all locations and 40.000 maximum at 150 pct all locations and 3.000 minimum at 150 pct all locations and 0.080 minimum at 600 pct all locations and 90.000 maximum at 125 pct all locations

  • Nonturn Device Length

    0.130 inches nominal

  • Case Material

    plastic

  • Switch Location And Position Designation

    internal at pole one

  • Body Width

    1.500 inches nominal

  • Nonturn Device Radius

    0.656 inches nominal

  • Terminal Type And Quantity

    4 quick disconnect, male

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3500.0 ac all locations

  • Switch Terminal Type

    quick disconnect, male

  • Thread Series Designator

    un

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Inclosure Protection Type For Which Designed

    shock resistant and hermetically sealed and vibration resistant

  • Maximum Continuous Load Current Rating Per Pole

    1.7 amperes ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Frequency In Hertz

    50.0 all locations or 60.0 all locations

  • Center To Center Distance Between Terminals Parallel To Length

    1.530 inches nominal

  • Arc Quenching Method

    magnetic blowout

  • Switch Current Rating And Type In Amps

    10.0 ac and 5.0 dc

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Bushing Length

    0.625 inches nominal

  • Manual Actuator Type And Quantity

    1 toggle

  • Mounting Surface To Terminal End Distance

    2.200 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...