Technical Characteristics

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2500.0 ac single location and 2500.0 dc single location

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.437 inches

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac single location and 28.0 dc single location

  • Trip Release Characteristic

    time delay single location

  • Unpackaged Unit Weight

    0.055 pounds

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Frequency In Hertz

    400.0 single location

  • Body Style

    single pole type

  • Bushing Length

    0.219 inches minimum and 0.281 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Terminal Type And Quantity

    2 tab w/screw

  • Thread Series Designator

    un

  • Body Width

    0.593 inches maximum

  • Nonturn Device Width

    0.073 inches minimum and 0.082 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.469 inches minimum and 0.531 inches maximum

  • Fragility Factor

    moderately rugged

  • Trip Release Method

    magnetic single location

  • Inclosure Protection Type For Which Designed

    shock resistant and vibration resistant

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Body Length

    0.781 inches maximum

  • Storage Type

    general purpose warehouse

  • Specification/Standard Data

    96906-ms3320 government specification

  • Actuator Function

    trip-reset

  • Maximum Continuous Load Current Rating Per Pole

    3.0 amperes ac single location and 3.0 amperes dc single location

  • Mounting Surface To Terminal End Distance

    1.343 inches maximum

  • Nonturn Device Location

    at 12 oclock

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Manual Actuator Type And Quantity

    1 push-pull

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.500 minimum at 200 pct single location and 40.000 maximum at 200 pct single location

  • Nonturn Device Length

    0.035 inches minimum and 0.050 inches maximum

  • Pole Quantity

    1

  • Case Material

    metal

  • ~1

    data on certain environmental and performance

  • Test Data Document

    81349-mil-c-5809 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...