11-00151-001
Coils and Transformers
TRANSFORMER ASSEMBLY
11-00151-001
General Dynamics Ots Aerospace Inc.
TRANSFORMER ASSEMBLY
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Winding Operating Voltage
74.10 ac pounds per hour wet 1st component 2nd secondary and 70.90 ac pounds per hour wet 1st component 2nd secondary and 78.55 ac pounds per hour wet 1st component 2nd secondary and 41.50 ac pounds per hour wet 1st component 2nd secondary and 38.30 ac
-
~1
pounds per hour wet 1st component 2nd secondary
-
Winding Power Rating
2.56 volts-amperes 2nd component 3rd secondary
-
Dc Resistance Rating In Ohms
0.7932 2nd component 1st secondary
-
Center To Center Distance Between Mounting Facilities Parallel To Length
1.730 inches minimum single mounting facility single center group and 1.770 inches maximum single mounting facility single center group
-
Overall Length
2.390 inches minimum and 2.430 inches maximum
-
Dc Resistance Rating In Ohms
0.0886 1st component 1st secondary
-
Winding Function And Quantity
1 primary 2nd component and 4 secondary 2nd component
-
Reliability Indicator
not established
-
Dc Resistance Rating In Ohms
4.300 2nd component 3rd secondary
-
Winding Operating Current
100.0 milliamperes nominal b 2nd component 4th secondary
-
Winding Power Rating
19.44 volts-amperes 1st component 1st secondary
-
Input-Output Phase Relationship
single phase to single phase all components
-
Terminal Type And Quantity
30 turret
-
Frequency Rating
400.0 hertz nominal all components
-
Winding Tap Location (Non-Core)
multiple taps w/center tap 1st component 2nd secondary
-
Winding Operating Voltage
115.00 ac pounds per hour wet all components single primary
-
Rating Method
electrical all components all secondary
-
Winding Operating Voltage
159.70 ac pounds per hour wet 2nd component 2nd secondary
-
Winding Operating Current
15.0 milliamperes nominal b 2nd component 2nd secondary
-
Mounting Facility Quantity
4 single group
-
Winding Operating Voltage
56.90 ac pounds per hour wet 2nd component 1st secondary and 14.70 ac pounds per hour wet 2nd component 1st secondary and 71.60 ac pounds per hour wet 2nd component 1st secondary
-
Winding Tap Location (Non-Core)
center tap 2nd component 2nd secondary
-
Winding Function And Quantity
1 primary 1st component and 2 secondary 1st component
-
Winding Operating Voltage
24.30 ac pounds per hour wet 1st component 1st secondary
-
Overall Height
5.068 inches minimum and 5.088 inches maximum
-
Winding Operating Voltage
25.60 ac pounds per hour wet 2nd component 3rd secondary
-
Test Data Document
16340-11-00151 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Dc Resistance Rating In Ohms
0.700 all components single primary
-
Winding Operating Voltage
26.20 ac pounds per hour wet 2nd component 4th secondary
-
Winding Operating Current
1.7 amperes nominal b all components single primary
-
Winding Tap Location (Non-Core)
multiple taps w/center tap 2nd component 1st secondary
-
Winding Power Rating
195.5 volts-amperes all components single primary
-
Overall Width
2.117 inches minimum and 2.217 inches maximum
-
Winding Operating Current
800.0 milliamperes nominal b 1st component 1st secondary
-
Winding Operating Current
640.0 milliamperes nominal b 2nd component 1st secondary
-
Rating Method
electrical all components single primary
-
Maximum Operating Temp
104.0 deg celsius
-
Winding Power Rating
44.96 volts-amperes 1st component 2nd secondary
-
Dc Resistance Rating In Ohms
52.200 2nd component 2nd secondary
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.410 inches minimum single mounting facility single center group and 1.450 inches maximum single mounting facility single center group
-
Dc Resistance Rating In Ohms
7.800 1st component 2nd secondary
-
Winding Power Rating
2.4 volts-amperes 2nd component 2nd secondary
-
Maximum Transformer Power Rating
195.5 volt-ampere all components
-
Winding Tap Location (Non-Core)
center tap 1st component 1st secondary
-
Mounting Method
slot single group
-
Winding Power Rating
2.62 volts-amperes 2nd component 4th secondary
-
Winding Operating Current
75.0 milliamperes nominal b and better 1st component 2nd secondary and 400.0 milliamperes nominal b and better drop siding 1st component 2nd secondary
-
Mounting Slot Width
0.115 inches minimum single group and 0.135 inches maximum single group
-
Winding Power Rating
45.824 volts-amperes 2nd component 1st secondary
-
Inclosure Type
fully inclosed
-
Component Name And Quantity (Non-Core)
2 transformer
-
Dc Resistance Rating In Ohms
0.540 2nd component 4th secondary
-
Winding Operating Current
100.0 milliamperes nominal b 2nd component 3rd secondary
-
Winding Shielding Method
internal shield brought out to terminal all components