G267879-1
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
G267879-1
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Maximum Dielectric Withstanding Dc Voltage
1.0 kilovolts at sea level
-
Maximum Voltage Drop Per Function
1.15 volts ac 2nd radio interference
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
5.490 inches minimum and 5.510 inches maximum
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 1st radio interference 1st function
-
Mounting Facility Type And Quantity
4 threaded hole
-
Body Material
metal
-
Functional Terminal Type And Quantity
1 connector, receptacle input 1st function
-
Input Terminal Manufacturer Code
32076
-
Vibration Resistance Range In Hertz
+5.0/+33.0
-
Maximum Voltage Drop Per Function
1.15 volts ac 1st radio interference
-
Functional Terminal Type And Quantity
3 tab, solder lug output 2nd function
-
Load Impedance Per Function
50.0 ohms 3rd radio interference
-
Operating Current Rating Per Function In Amps
1.0 1st radio interference
-
Principal Circuitry Type Per Function
inductance-resistance 3rd radio interference
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference
-
Body Width
3.970 inches minimum and 4.030 inches maximum
-
Body Height
1.470 inches minimum and 1.530 inches maximum
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 3rd radio interference 3rd function
-
Overall Length
6.160 inches minimum and 6.240 inches maximum
-
Power Line Frequency Rating Per Function In Hertz
60.0 2nd radio interference
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Functional Terminal Type And Quantity
1 tab, solder lug ground 3rd function
-
Power Line Frequency Rating Per Function In Hertz
60.0 3rd radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance-resistance 2nd radio interference
-
Inclosure Type
hermetically sealed
-
Operating Current Rating Per Function In Amps
1.0 3rd radio interference
-
Unpackaged Unit Weight
2.730 pounds
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Body Length
5.970 inches minimum and 6.030 inches maximum
-
Maximum Voltage Drop Per Function
1.15 volts ac 3rd radio interference
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 2nd radio interference 2nd function
-
Style Designator
rectangular terminal/terminals on two surfaces
-
Operating Temp Range
-55.0/+71.0 deg celsius
-
Principal Circuitry Type Per Function
inductance-capacitance-resistance 1st radio interference
-
Power Line Frequency Rating Per Function In Hertz
60.0 1st radio interference
-
Mounting Facility Screw Thread Series Designator
unc
-
Nominal Thread Size
0.164 inches
-
Operating Current Rating Per Function In Amps
1.0 2nd radio interference
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
3.490 inches minimum and 3.510 inches maximum
-
Overall Height
2.280 inches minimum and 2.400 inches maximum
-
Input Terminal Identification
a3102r/e-20-4p