NJL631400MT0

Circuit Breakers

CIRCUIT BREAKER

NJL631400MT0

5925-01-318-9443

5925 - Circuit Breakers

Challenger Electrical Equipment Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Features Provided

    adjustable trip release

  • Nominal Thread Size

    0.500 inches

  • Storage Type

    general purpose warehouse

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Actuator Function

    trip-reset

  • Switch Terminal Type

    wire lead

  • Body Width

    8.250 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac all locations and 250.0 dc all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    7.250 inches nominal

  • Inclosure Protection Type For Which Designed

    moisture proof and fungus proof

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Actuator Position Designation

    at pole two

  • Switch Contact Arrangement

    single pole, double throw

  • Body Style

    multipole-single actuator type

  • Boss Height

    0.250 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    9.120 inches nominal

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Thread Quantity Per Inch

    13

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    150000.0 ac all locations and 220000.0 dc all locations

  • Terminal Type And Quantity

    6 compression

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Body Height

    4.080 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.220 inches nominal

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Maximum Continuous Load Current Rating Per Pole

    400.0 amperes ac all locations and 400.0 amperes dc all locations

  • Mounting Facility Type And Quantity

    4 threaded stud

  • Center To Center Distance Between Terminals Parallel To Width

    1.880 inches nominal

  • Switch Location And Position Designation

    internal at pole one

  • Case Material

    plastic

  • Fragility Factor

    moderately rugged

  • Adjustable Trip Setting Current Range Per Pole In Amps

    +3000.0/+4800.0 ac all locations

  • Body Length

    10.120 inches nominal

  • Trip Release Characteristic

    instantaneous all locations

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Switch Voltage Rating And Type In Volts

    250.0 ac

  • Thread Series Designator

    unc

  • Switch Current Rating And Type In Amps

    5.0 ac

  • Reset Method

    manual

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...