MIL-C-5809
Circuit Breakers
CIRCUIT BREAKER
MIL-C-5809
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Maximum Continuous Load Current Rating Per Pole
15.0 amperes dc single location
-
Body Length
1.575 inches maximum
-
Terminal Type And Quantity
2 screw
-
Body Width
0.780 inches maximum
-
Operating Voltage Type And Rating Per Pole In Volts
115.0 ac single location and 28.0 dc single location
-
Overall Length
2.319 inches nominal
-
Main Contact Tripping Mechanism Type
trip free
-
Center To Center Distance Between Terminals Parallel To Length
0.703 inches nominal
-
Frequency In Hertz
400.0 single location