M83383/02-10
Circuit Breakers
CIRCUIT BREAKER
M83383/02-10
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Unthreaded Mounting Hole Diameter
0.172 inches nominal
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3600.0 ac single location and 3600.0 dc single location
-
Frequency In Hertz
400.0 single location
-
Main Contact Tripping Mechanism Type
trip free
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location
-
Trip Release Characteristic
time delay single location
-
Mounting Facility Type And Quantity
2 unthreaded hole
-
Operating Voltage Type And Rating Per Pole In Volts
115.0 ac single location and 28.0 dc single location
-
Auxiliary Trip Coil Voltage Type And Rating In Volts
115.0 ac nominal single location and 28.0 dc nominal single location
-
Pole Quantity
1
-
Features Provided
trip indicator
-
Trip Release Method
thermal single location
-
Circuit Protection Type
overcurrent single location
-
Inclosure Protection Type For Which Designed
corrosion resistant and shock resistant and explosion resistant and dustproof and moisture resistant and sand resistant and humidity resistant and vibration resistant
-
Maximum Continuous Load Current Rating Per Pole
60.0 amperes ac single location and 60.0 amperes dc single location
-
Reset Method
electric
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.260 minimum at 1000 pct single location and 13.000 maximum at 400 pct single location and 13.000 minimum at 200 pct single location and 60.000 maximum at 200 pct single location and 2.600 minimum at 400 pct single location and 1.800 maximum at 1000 pct
-
Internal Trip Release Configuration
series trip w/auxiliary load terminal and remote trip feature single location
-
~1
single location