Technical Characteristics

  • Operating Voltage Type And Rating Per Pole In Volts

    18.0 dc fourth location

  • External Actuator Linkage Arrangement

    one, two, three, and four linked

  • Trip Release Characteristic

    time delay first location

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac second location

  • Circuit Protection Type

    overcurrent third location

  • Body Style

    multipole-multiple actuator type

  • Trip Release Method

    magnetic all locations

  • Mounting Surface To Terminal End Distance

    2.611 inches nominal

  • Unpackaged Unit Weight

    12.500 ounces

  • Mounting Facility Type And Quantity

    8 threaded hole

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent second location

  • Internal Trip Release Configuration

    series trip all locations

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

  • Circuit Protection Type

    overcurrent first location

  • Center To Center Distance Between Terminals Parallel To Length

    1.928 inches minimum and 1.948 inches maximum

  • Frequency In Hertz

    400.0 first location

  • Reset Method

    manual

  • Actuator Position Designation

    at each pole

  • Thread Series Designator

    unc

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.100 minimum at 200 pct second location and 20.000 maximum at 200 pct second location

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac third location

  • Terminal Type And Quantity

    8 threaded stud

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Nominal Thread Size

    0.138 inches

  • Center To Center Distance Between Terminals Parallel To Width

    0.740 inches minimum and 0.760 inches maximum

  • Trip Release Characteristic

    time delay second location

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac first location

  • Inclosure Protection Type For Which Designed

    corrosion resistant and shock resistant and moisture resistant and vibration resistant

  • Fragility Factor

    moderately rugged

  • Manual Actuator Type And Quantity

    4 toggle

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac second location

  • Boss Height

    0.130 inches minimum and 0.150 inches maximum

  • Body Width

    2.970 inches minimum and 3.030 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac third location

  • Case Material

    plastic

  • Pole Quantity

    4

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac first location

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac second location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.100 minimum at 200 pct third location and 20.000 maximum at 200 pct third location

  • Frequency In Hertz

    400.0 second location

  • Circuit Protection Type

    overvoltage fourth location

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Trip Release Characteristic

    time delay third location

  • Trip Release Characteristic

    instantaneous fourth location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.052 inches minimum and 2.072 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac first location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac third location

  • Frequency In Hertz

    400.0 third location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.100 minimum at 200 pct first location and 20.000 maximum at 200 pct first location

  • Body Length

    2.490 inches minimum and 2.510 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...